DATA
CENTER
CABLING.

- STANDARDS
- TIA-942 · BICSI-002 · J-STD-607-C
- COPPER
- CAT6A U/UTP · F/UTP · Shielded
- FIBER
- OS2 · OM4 · OM5 · MTP/MPO
- SPEEDS
- 10G · 25G · 40G · 100G · 400G
- CABINETS
- 42U / 45U / 48U · Colo & In-row
- CONTAINMENT
- Hot aisle · Cold aisle · Chimney
- POWER
- Vertical & Horizontal PDUs · A/B Feeds
- TESTING
- Fluke DSX · OLTS · OTDR bidirectional
Level and land 2-post relay racks and full 42U-48U cabinets, install roof blanking, brush grommets, and hot- or cold-aisle containment panels. Airflow-planned with your electrical and mechanical team.
Separated overhead ladder rack for copper and basket tray for fiber, tiered where required. Bonded and grounded to the TMGB per J-STD-607-C so the pathway itself meets code.
Pre-terminated 12- and 24-fiber MTP trunks between rows, cassettes and LC breakouts at each cabinet. Sized to spine-and-leaf topologies so 40G/100G/400G upgrades don't touch the plant.
High-density angled patch panels, shielded or unshielded CAT6A per your standard, patch cords cut to length and dressed in horizontal management. Every port labeled to your naming convention.
Vertical PDU install on A and B feeds, cabinet bonding to the SRG/CBN, and door and side-panel bonding jumpers so every metallic component is at ground.
Ongoing move / add / change work, MTP and LC cross-connects, and cabinet re-grooms in occupied production rooms — scheduled to your change window with full test and documentation on hand-back.
- Enterprise on-prem data center buildout
- Colocation cabinet fit-out and cross-connects
- Server-room / MDF expansion
- Spine-and-leaf 40G/100G migration
- Data-center consolidation & decommission
- MAC and cabinet re-groom programs
- Q-01
- Yes. We handle greenfield data-center builds, MDF/server-room fit-outs, and expansions across Orange County — including cabinets, hot/cold aisle containment, overhead ladder rack and basket tray, structured copper and fiber, grounding, and full labeling to your naming convention.
- Q-02
- For copper we install CAT6A shielded or unshielded per your standard, terminated at high-density angled patch panels. For fiber we install OS2 single-mode and OM4/OM5 multi-mode with MTP/MPO trunks and LC breakouts sized to spine-and-leaf topologies at 10/25/40/100G and beyond.
- Q-03
- Yes. We land and level cabinets, install vertical PDUs, blanking panels, brush grommets, and hot- or cold-aisle containment. Grounding is bonded to the room's TMGB per J-STD-607-C. We coordinate with your electrical contractor on branch circuits and static-transfer switches.
- Q-04
- Yes. Move/add/change work, patching, and MTP/LC cross-connects are performed to your change-window schedule — nights, weekends, and maintenance windows. All new terminations are Tier 1 and Tier 2 tested and documented before we hand back.
- Q-05
- Yes. Data-center cabling is designed and installed to ANSI/TIA-942 and BICSI ANSI/BICSI-002, with awareness of Uptime Institute Tier requirements for cabling pathways, redundancy, and separation. We deliver as-built drawings, port maps, and Fluke / OTDR test packages.