(657) 452-0478
S-01 · COPPER · TIA-568

CAT6 &
CAT6A
CABLING.

Commercial CAT6 and CAT6A horizontal cabling installed to TIA/EIA-568 and BICSI ANSI/BICSI-002. Every drop is pulled clean, dressed at the patch panel, certified with a Fluke DSX-5000, and delivered with a labeled test report and manufacturer channel warranty.
Technician terminating CAT6A cable onto a patch panel in an OC server rack
// FIELD PHOTO · ORANGE COUNTY, CA
01SPEC
CATEGORY
CAT5e · CAT6 · CAT6A
BANDWIDTH
Up to 500 MHz (CAT6A)
SPEED
1 / 2.5 / 5 / 10GBASE-T
POE SUPPORT
IEEE 802.3af / at / bt (90W)
CHANNEL LIMIT
100 m (328 ft)
CERT
Fluke DSX-5000 · TIA-568
JACKET
Plenum (CMP) · Riser (CMR)
MFR
Panduit · CommScope · Leviton · Belden
02WHAT WE INSTALL
01
Horizontal drops to workstations, WAPs, cameras

New and add-on runs to workstations, wireless access points, IP cameras, printers, digital signage, and access-control panels. Two data drops per desk is standard, more for conference and huddle rooms.

02
Patch panels, jacks, and faceplates

24- and 48-port angled or flat patch panels, keystone jacks, single- and multi-gang faceplates, and surface-mount boxes — all matched to the chosen manufacturer channel for warranty coverage.

03
Cable pathways and firestopping

J-hooks, cable tray, basket tray, EMT/conduit sleeves, and fire-rated pathway devices through rated walls. Installed to NEC and OSHA-30 standards.

04
Termination, labeling, and Fluke certification

T568B termination as default, every jack labeled to your naming convention, and every run channel-tested with a full PDF report per drop.

03TYPICAL PROJECTS
  • New office tenant improvement (10 – 500 desks)
  • Warehouse & industrial low-voltage packages
  • Retail & restaurant fit-outs
  • Medical & dental office cabling
  • Wi-Fi 6 / 6E WAP drop programs
  • MAC work in occupied Class A office space
04FAQ
Q-01
Should I install CAT6 or CAT6A?
For most new commercial installs today we recommend CAT6A. It supports 10GBASE-T at the full 100-meter channel and is what large enterprises and data-center cross-connects standardize on. Standard CAT6 remains fine for 1-Gigabit access-layer runs under 55 meters and is often more budget-friendly for smaller offices.
Q-02
What is the maximum run length for CAT6 cable?
The TIA channel limit is 100 meters (328 feet) end-to-end, including patch cords. Beyond that you need to break the run with an IDF or move to fiber. We plan pathways during the site survey so no drop violates the channel budget.
Q-03
Do you certify every CAT6 and CAT6A run?
Yes. Every horizontal run is certified with a Fluke DSX-5000 or newer, and we deliver PDF test reports for wire-map, insertion loss, NEXT, PSNEXT, return loss, and delay skew. You get the raw results, not just a pass/fail sticker.
Q-04
Which CAT6 manufacturers do you install?
We install Panduit, CommScope Netconnect, Leviton Atlas-X1, and Belden systems. Choosing a full manufacturer channel (cable + jack + patch panel + patch cords from the same vendor) is what unlocks the 25-year performance warranty.
Q-05
Can you add new CAT6 drops without disturbing occupied offices?
Yes. Add-on and move/add/change (MAC) work is a core part of what we do. Runs are pulled from ceiling plenum or under raised floor with minimal impact, terminated at the existing patch panel, tested, and labeled to match your naming convention.