Commercial CAT6 and CAT6A horizontal cabling installed to TIA/EIA-568 and BICSI ANSI/BICSI-002. Every drop is pulled clean, dressed at the patch panel, certified with a Fluke DSX-5000, and delivered with a labeled test report and manufacturer channel warranty.

01SPEC
- CATEGORY
- CAT5e · CAT6 · CAT6A
- BANDWIDTH
- Up to 500 MHz (CAT6A)
- SPEED
- 1 / 2.5 / 5 / 10GBASE-T
- POE SUPPORT
- IEEE 802.3af / at / bt (90W)
- CHANNEL LIMIT
- 100 m (328 ft)
- CERT
- Fluke DSX-5000 · TIA-568
- JACKET
- Plenum (CMP) · Riser (CMR)
- MFR
- Panduit · CommScope · Leviton · Belden
02WHAT WE INSTALL
01
Horizontal drops to workstations, WAPs, cameras
New and add-on runs to workstations, wireless access points, IP cameras, printers, digital signage, and access-control panels. Two data drops per desk is standard, more for conference and huddle rooms.
02
Patch panels, jacks, and faceplates
24- and 48-port angled or flat patch panels, keystone jacks, single- and multi-gang faceplates, and surface-mount boxes — all matched to the chosen manufacturer channel for warranty coverage.
03
Cable pathways and firestopping
J-hooks, cable tray, basket tray, EMT/conduit sleeves, and fire-rated pathway devices through rated walls. Installed to NEC and OSHA-30 standards.
04
Termination, labeling, and Fluke certification
T568B termination as default, every jack labeled to your naming convention, and every run channel-tested with a full PDF report per drop.
03TYPICAL PROJECTS
- New office tenant improvement (10 – 500 desks)
- Warehouse & industrial low-voltage packages
- Retail & restaurant fit-outs
- Medical & dental office cabling
- Wi-Fi 6 / 6E WAP drop programs
- MAC work in occupied Class A office space
04FAQ
- Q-01
- For most new commercial installs today we recommend CAT6A. It supports 10GBASE-T at the full 100-meter channel and is what large enterprises and data-center cross-connects standardize on. Standard CAT6 remains fine for 1-Gigabit access-layer runs under 55 meters and is often more budget-friendly for smaller offices.
- Q-02
- The TIA channel limit is 100 meters (328 feet) end-to-end, including patch cords. Beyond that you need to break the run with an IDF or move to fiber. We plan pathways during the site survey so no drop violates the channel budget.
- Q-03
- Yes. Every horizontal run is certified with a Fluke DSX-5000 or newer, and we deliver PDF test reports for wire-map, insertion loss, NEXT, PSNEXT, return loss, and delay skew. You get the raw results, not just a pass/fail sticker.
- Q-04
- We install Panduit, CommScope Netconnect, Leviton Atlas-X1, and Belden systems. Choosing a full manufacturer channel (cable + jack + patch panel + patch cords from the same vendor) is what unlocks the 25-year performance warranty.
- Q-05
- Yes. Add-on and move/add/change (MAC) work is a core part of what we do. Runs are pulled from ceiling plenum or under raised floor with minimal impact, terminated at the existing patch panel, tested, and labeled to match your naming convention.
Should I install CAT6 or CAT6A?
What is the maximum run length for CAT6 cable?
Do you certify every CAT6 and CAT6A run?
Which CAT6 manufacturers do you install?
Can you add new CAT6 drops without disturbing occupied offices?